NEW Dulux Professional Ceiling Flat-White has an ultra-flat sheen level for an exceptional finish. It has advanced formula for superior, smooth, low spatter application and excellent coverage for superior hiding power. Dulux Professional Ceiling has improved wet edge time and is easier to touch-up, which helps deliver a uniform finish. It is low odour and low VOC. Dulux Professional® Ceiling Flat has added mould resistance that helps protect in humid environments.
All preparation and painting must conform to AS2311: The Painting of Buildings.
Do not paint at temperatures below 10C or when the temperature of surface may fall below 10C during the drying period.
Previously painted surfaces :
Surfaces must be sanded to remove loose, peeling, flaking or chalky paint. Fill any cracks or holes with a suitable filler. Sand all gloss and semi
gloss surfaces to a dull finish and wipe down with a damp cloth to remove surface dust. Apply one coat of Dulux Professional Acrylic Sealer
Undercoat or Dulux Professional Total Prep® Acrylic to any areas that have been repaired or which have an uneven gloss level.
Bare paperfaced plasterboard:
Apply one coat of Dulux Professional Acrylic Sealer Undercoat or Dulux Professional Total Prep Acrylic.
Bare set plaster, fibrous plaster, plasterglass
Apply one coat of Dulux Professional Oil Based Primer Sealer Undercoat. For best results on bare set plaster and powdery surfaces apply one
coat of an appropriate sealer binder.
Application Procedure and Equipment
Stir contents thoroughly before and during use with a broad flat stirrer, using an upward lifting action. Apply two coats of Dulux Professional
Ceiling Flat Premium Acrylic ensuring that the first coat is completely dry before applying the second.
Brush/Roller
Rinse brush or roller in water before starting and use while still slightly damp.
Apply full even coats direct from the container. Under hot conditions or on very absorbent surfaces, up to 100ml clean water may be added per
litre to assist application.
Airless/Conventional Spray
Suitable for application by all standard spray equipment. If necessary thin with up to 100ml per litre of water to aid atomisation.